A-Frame (overhead battery exchange)
September 2007
Hydraulic system simplified by using ‘sandwich’ manifold and flow control valve to replace shuttle valve, flow control valve, and tee manifold assembly. New system provides wider speed control and faster response.

January 2007
Single Track A-Frame updated with 18 tooth drive/driven sprockets on both flanged and poly wheels. This allows use of same drive wheel box on both flanged and poly wheels, poly drive wheel requires 1” spacer between drive wheel box and frame channel.

Battery Wash System
March 2012
B801639B rev. A re-plumbing to 3/4 NPT injector View

March 2012
D801175B water spray manifold with PVC pipe. View

March 2010 Pico PLC replaces MicroLogix on Model A washers, new schematic is D801333E.

March 2010 All solenoids used on all AWC’s will now have 115VAC coils, conversion easily accomplished on older AWC’s – see ‘AWC-A update to 115VAC solenoids.pdf’ for details. View

 


Hydra Handler System
April 2012
Centurion travel flow control cartridge valve updated to 7GPM version to provide higher floor travel speed. 8836 PWM card updated to high resolution version to provide easier setup. Both updates are functionally equivalent to previous components; besides providing better performance (i.e. they should not cause and issues) View

June 2010
806830B-RLTR circuit added to Centurion 806830B schematic to provide redundancy to lift and travel PLC outputs to protect against PLC output relay failure. View

June 2010 806830B-RRDC circuit added to Centurion 806830B schematic to provide redundancy to roller deck function PLC outputs to protect against PLC output relay failure. View

June 2010 A806245A HHA Hose Routing Inner Frame to I-Beam Retrofit Kit for Standard Hydra Handler. Converting eliminates the severe twisting of hydraulic and vacuum hoses, and electrical cables that occurs with the original routing. Conversion will take approximately three man-hours to complete. View

August 2009 500W magnet, 9208, replaces 8749 magnet. Requires use of relay, PN 1958, due to high amp draw (20A). Centurion Hydra Handler View

August 2009
500W magnet, 9208, replaces 8749 magnet. Requires use of relay, PN 1958, due to high amp draw (20A). Standard Hydra Handler View

August 2009
Hall Effect joystick, 7097A, is now standard on all Centurions. See’Upgrade to Hall Effect Joystick 7097A.pdf’. View

January 2006 Conversion from 3 Solenoid to 1 Solenoid Vacuum System on older Standard Hydra Handlers. Converting removes solenoid valves from extractor arm where they are prone to damage and creates a positive air pressure to release the battery from the left (right) cup when the selector switch is set for right (left) cup vacuum, which also blows dirt out of the vacuum line. View

Battery Charging Stands
December 2007
Plastic decks detailed for use on wood stands, direct replacement for wood decks.

Transfer Carts (side removal battery exchange)
September 2011